close

Buy APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U in United States - Rehmie.com

APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U

REP14048 0731304331568 REP14048

APC by Schneider Electric

APC by Schneider Electric
2025-04-26 USD 1515.57

$ 1,515.57 $ 1,578.72

Item Added to Cart

*Product availability is subject to suppliers inventory

APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U
SHIPPING ALL OVER UNITED STATES
APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U
100% MONEY BACK GUARANTEE
APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U
EASY 30 DAYSRETURNS & REFUNDS
APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U
24/7 CUSTOMER SUPPORT
APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U
TRUSTED AND SAFE WEBSITE
APC by Schneider Electric Rack PDU, Switched, 1U, 15A, 100/120V, (8)5-15 - Switched - NEMA 5-15P - 8 x NEMA 5-15R - 120 V AC - 1440 W - 1U
100% SECURE CHECKOUT
Model name: AP7900B
Warranty: 2 Year Limited Warranty. To obtain a copy of the manufacturer's or supplier's warranty for this item prior to purchasing the item,
• Input Voltage: 120 V AC
• Output Receptacles: 8 x NEMA 5-15R
• Input Receptacles: 1 x NEMA 5-15P
• PDU Type: Switched
• Output Voltage: 120 V AC
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power cycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing time delays allow users to define the order in which to power up or down attached equipment to avoid circuit overload. Current metering provides real-time remote monitoring of connected loads with user-defined alarms to warn of potential circuit overloads. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by APC Centralized Management platforms using StruxureWare Data Center Expert, Operations, Capacity, and Energy Efficiency. New AP8000 series Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles.