AUTOOL SDT208 smoke detector, pipeline leak detection for vehicles in fuel systems and cooling systems
Product Description:
The AUTOOL SDT208 Smoke Detector is designed for pipeline leak detection of vehicles' air intake system, fuel system, and cooling system.
It is suitable for all family cars, motorcycles, snowmobiles, off-road vehicles, ATVs, light trucks and speedboats.
It is the golden partner of the car diagnostic instrument.
It can be used with the car diagnostic instrument to accurately determine the location of the physical fault of the car and
quickly detect the hidden fault of the car engine.
Parameters:
Input Voltage 12V/ 24V
Pressure Control Built-in
Smoke output ≥6L/ Min
Operation time for one test 15 min
Flow control Built-in
Pressure maintain 2 sets
Operation:
1. After assembling the smoke leak detector, inject about 30ML smoke oil for the first time.
The test oil for each injection should not exceed MAX scale. It is suggested that the testing operation should not exceed 15 minutes.
2. Open the engine cover and remove the air filter. Some vehicles need to remove the air flow sensor.
3. Put the intake bladder/ adapter into the intake hose of the engine to block the pipe, and press it hard until the intake hose is sealed.
4. Connect the power cord to the car battery, the red clamp to the positive electrode of the battery,
and the black clamp to the negative electrode.
5. Turn on the power control switch, the POWER lights up, indicating that the power supply of the smoke generator is normal.
6. After pressing the STANDARD MODE switch, then pressing the AIR START switch, the air pump starts to work.
Only when the air pump starts, the SMOKE START switch can be pressed to start work.
7. After pressing the AIR START switch and the air pump starts work, pay attention to the pressure gauge calibration.
If the pressure gauge calibration exceeds 15 PSI, the flowmeter beads sink to the bottom and remain unchanged,
this indicates that no leakage has been detected. If the pressure rises slowly and the flow meter monitors the air inflow all the time,
it is necessary to check whether the assembling and parts are installed properly.
After no error found, the system is confirmed to have leakage, press the SMOKE START button.
8. Smoke starts when SMOKE START switch is pressed. After smoke start-up, OVER HEAT PROTECTION lights up if the oil in the machine is insufficient or the continuous working time is too long, resulting in overheat of the system.
It will resume work until the temperature drops to the normal range.
9. According to different types of vehicles, about 1 minute after the start of smoke, the engine pipeline will be filled with smoke,
and the system leakage point will be checked.
10. At the end of the inspection, take off the power cord and keep the accessories for next use.
The main body of the intake bladder/ adapter is made of rubber. Please avoid expose to corrosive liquids such as gasoline.
Detection Method of Fuel Evaporative Emission Control System (EVAP)
Since 1996, cars manufactured in the United States have been equipped with EVAP service ports;
in most American cars, EVAP service ports are usually located in engine compartments,
but some special models of EVAP service ports may be located in other locations.
EVAP routine detection method: open the plastic cap of the EVAP service port, then remove the one-way valve clockwise using
the valve core wrench, then install the adapter of the EVAP service port, then import smoke from this port into the EVAP system
for leakage detection.
Judgment of Leakage Condition
If the machine is equipped with pressure gauge products, you can first not to open the smoke generator switch, block the smoke outlet,
observe and confirm the pressure gauge readings, and compare the pressure gauge readings in the detection process.
If the pressure gauge readings can continue to rise and maintain rising up, this indicates that there is no leakage in the system;
if the pressure gauge readings decline, indicating that the system has leakage.
If the pressure gauge reading is zero, it means the size of the leakage point is more than 0.3 mm.
About Smoke Oil
This product can function with ordinary fume oil or baby oil. The selected fume oil must be pure, non-aqueous liquid and in a fluid state.
Do not use sticky or dense smoke oil, which can easily damage the machine.
If the product failures are caused by improper use of smoke oil, this shall not be covered by the product warranty.
When adding smoke oil, please use the pointed measuring bottle.
If the oil exceeds the MAX, please open the oil outlet port and discharge the appropriate amount of fume.
Packing List:
1pcs * Smoke Machine Main Unit
1pcs * Black Pipeline Plug
1pcs * Smoke Pipe
1pcs * Red Pipeline Plug
1pcs * Storage Box
1pcs * Scaled Oil Bottle
1pcs * Power Cord
1pcs * Cone Inlet Adapter
1pcs * Adapter
1pcs * Intake Adapter
1pcs * Valve Core Wrench
1pcs * User's Manual
1pcs * EVAP Adapter
1pcs * Certificate card
Caution
Non- technical person shall not change, disassemble or repair the product, otherwise all losses caused by this shall be bared by the user himself.
This product is not suitable for leak detection of smoke sensitive parts such as headlight assemblies.
This product can only be powered by 12V car battery, the positive and negative poles can not be reversed.
Before placing the universal air intake bladder into the engine intake hose, clean the inner hose of the bladder to ensure that there is no spikes, in order to avoid spikes pierce the air inlet bladder.
If the smoke is becoming weaker during use, it indicates that the oil is insufficient and please fill in oil in time.
The product has overheat protection device, when the Over Heat Protection light is red, the smoke will stop output. When the temperature decrease to the normal range, the device will resume operation. The cycle is about 5 minutes, so you don't have to worry about it.
Warranty
There are 3 years’ warranty for AUTOOL products and the accessories since the day the customers have received the product parcel.
Warranty Access
1. Repair or replace the equipment will be done according to the specific fault conditions;
2. We guarantee that all replacement parts, accessories or equipment are brand new;
3. When there is a product breakdown that can not be solved within 90 days, customer should provide video and pictures as proof, we will bear the freight cost and provide customer the accessories in need to replace. After receiving the product for more than 90 days, the customer shall bear the freight cost, we will provide the accessory for free to replace.
Warranty not Covered in Conditions Listed Below:
1. Product is bought through non-official AUTOOL purchase channel.
2. Product failure is caused by incorrect use of the product, use for other wrong purpose or human factors.
Disclaimer: The AUTOOL Technology Co, Ltd. reserves the right to change product designs and specifications without prior notice. The physical appearance and color may differ from those shown in the instruction manual. Please refer to the actual product. If you have any questions, please contact the dealer or the Autool service center. The company have the final explanation right of product and shall not bear any consequences due to misunderstanding.
PRODUCT RECOMMEND: