Upgraded SDT-206 is designed for detecting the leakage of pipe systems on cars, motorcycles, such as fuel pipe, air intake system and cooling tank.
Working principle:
create smoke through the equipment and sent smoke to sealed car pipeline system
(Such as air intake systems, exhaust systems, fuel systems, air conditioning systems,cooling tank etc.)
Where there is smoke in the pipeline, there is a leak
FAQ
1.What Kind Of Oil Use This Product To Product The Smoke?
Liquid Paraffn And Baby Oil Are OK, Easy To Find It
2. HOW TO DO LEAKAGE TEST?
① Turmn On Device Then Block Smoke Exhaust Port, Record Pressure Gauge Value.
②. Connect Smoke Exhaust Port To The Pipe System You Want To Test
③. Wait For A While. Pressure Gauge Value Decrease Means The Pipe System Have Leakage, Pres-sure Gauge Value Show "O" Means Diameter Of Leakage Point Is More Than 0. 3mm
Upgraded SDT-206 is for all pipe systems and EVAP.
EVAP is a fuel evaporation control system used to collect and deal with fuel vapor, to prevent fuel vapor leakage. If the leak will pollute the atmosphere and even cause the vehicle to spontaneous combustion.
Plus this set of accessories can detect the smoke of the EVAP system, check whether there is leakage, broken, enhanced traffic safety
Note : pls contact me ask for the item's video if u need.
Cautions:
1.When you use this detector the first time, please fill 20-30ml oil, not beyond this range.
2.New oil can be filled with only when the smoke is light, and it can't be filled over 15ml every time.
3.Before filling new oil, please pour out the remaining oil in the detector.
4.Please replace the detector oil regularly.
How to use:
1.Open the engine cover, and hang the detector in the cover.
2.Disconnect the pipe that needs to be connected with detector. If the pipe needs to be disconnected in the middle.
Please secure the other side with a rubber stopple.
3.Secure this side with proper taper stopple/pipe, and connect it with smoke output tube.
4.Connect detector with DC12V battery: red with positive, black with negative. Do not connect in a contrary way.
5.Turn on the power switch, and detector starts to work.
6.In about 3 minutes, the pipe will be filled with smoke. Check the leak points. Please use head lamp if necessary.
7.After leak detection, please connect well the wires and pipe.
Notes:
* Please do leak detection away from smoke-sensitive parts.
* Do not run the detector over 8 minutes. It needs interval rest.
* The detector has protector. If it exceeds working limit, it will power off automatically. In this condition, please operate it later.
* The round parts of this detector is with temperature, be careful to avoid scalding injury.
Product Description:
The AUTOOL SDT-206 Smoke Leak Detector is designed for pipeline leak detection in automotive air intake system, fuel system and cooling system. It is suitable for all family cars, motorcycles, snowmobiles, off-road vehicles, ATVs, light trucks and speedboats. It is the great partner of car diagnose tool. It works with the car diagnose tool to accurately locate the physical fault of the car and quickly detect the hidden fault of the car engine.
Machine Structure
A- Power switch of smoke generator. When the power is on, press this switch, the indicator POWER lights up, indicates that the smoke generator power is normal.
B-Power switch of air pump power. Press the AIR MODE, pump starts working, only after this, you may press and start the SMOKE MODE;
C- Switch of smoke. Press SMOKE MODE to start smoke smoke. In this mode, if the machine that has insufficient smoke oil, or the working time is too long, the system will get overheat and the ALARM light will light up until the temperature drops to the normal range, and the machine will resume operation;
D - Smoke oil filling port. The total amount of one-time filling does not exceed 100ml smoke oil, the scale does not exceed the MAX, the first filling amount increase higher than 100ml is normal.
E-Venting pipe. Through which smoke is into the automotive piping system;
F- Power socket. Plug in the power cable here to provide working power for the machine;
G- Visible window of barometer. If there is no leak in the system, you can observe through this window that the flowmeter stays at the bottom, the gauge pointer rises; if the system has a leak, the flowmeter floats up and the gauge pointer drops;
H- Pressure adjustment button, to adjust the smoke flow rate;
I- Pressure gauge. It can be changed by the pressure gauge indicator, and quickly observe whether the automobile pipeline system leaks;
J- Hook. It make it easy to fix the machine to the car.
K- Level gauge. It can help visual observation of the oil level and condition left inside the equipment. If the oil is yellow, the oil needs to be replaced.
L- Oil drain port. When the equipment is used, drain the oil to prevent the deposition of particles, and keep the internal seal of the equipment after emptying, to prevent the affect the function of the equipment.
Operation Steps:
1. After assembling the leak detector accessories, fill in about 100ML of smoke oil for the first time, the scale should not exceed the MAX indicator, the filling can work continuously for 15 minutes or so;
2. Open the engine cover and remove the air filter. For some models of cars, you need to remove the air flow sensor.
3. Place the air inlet adapter on the engine intake hose port and plug the pipe tightly, make sure it is closed inside without air.
4. Connect the power cable to the car battery. The red battery clip is connect the battery positive pole and the black clip connects the battery negative pole.
5. Turn on the power switch, the indicator light POWER lights up, indicating that the smoke generator is powered normally. Press the AIR MODE air pump to start working. Only after this mode is started, you may start SMOKE MODE;
6. After the AIR MODE air pump starts working, pay attention to the pressure gauge scale. If the scale exceeds 15 PSI, the flowmeter will sink and stay still at the bottom, indicating that there is no leak detected. If the pressure rises slowly, the flowmeter monitors that there is always air inflow, then it is necessary to check whether the access system is installed properly. If there is no mistake after checking, it is detected that there is leakage in the detected system, then press the SMOKE MODE button.
7. Press the SMOKE MODE button and the smoke starts running.In this mode, if the machine that has insufficient smoke oil, or the working time is too long, the system will get overheat and the ALARM light will light up until the temperature drops to the normal range, and the machine will resume operation;
8. For different models of cars, the engine interior will be full of smoke in about 1 minute, and the system will be checked for leak points;
9. After the inspection is completed, remove the power cable and collect the accessories for the next time. The body of air intake adapter (inlet air bag) is made of rubber, please avoid expose to corrosive liquids such as gasoline.
EVAPORATIVE EMISSION CONTROL SYSTEM (EVAP) DETECTION METHOD
The American cars produced after 1996 are equipped with EVAP service ports; The EVAP service ports are usually located in the engine compartment for most US cars but elsewhere for some special cars. Conventional EVAP detection method: Open the plastic cover of the EVAP service port, then remove the one-way valve clockwise with a valve wrench and install the EVAP service port adapter to import the smoke into the EVAP system for leak detection.
JUDGE ON THE LEAK STATUS
If the SDT-202 and SDT-206 models with pressure gauges are equipped, turn off smoke generator
Product Information:
Power: DC12V, vehicle battery
Smoke output value: 6l/min
Built-in air supply
Controllable flow value
Maintenance
With longtime high temperature, the smoke and oil will oxidize and deteriorate. It will infect the service life of smoke generated part, so please change smoke and oil regularly.
1.Before filling new oil, please pour out the remaining oil in the detector.
2.When the smoke output has water drops, please replace with new oil.
3.Liquid paraffin and baby oil are OK.
4.Please fill new oil with equipped oil bottle
WARRANTY ACCESS:
1. The repair or replacement of products is determined by the actual breakdown situation of product.
2. It is guaranteed that Autool will use brand new component, accessory or device in terms of repair or replacement.
3. If the product breakdown within 90 days after user receives product and provide video or picture proof, we will provide relevant components of product for customer to replace with freight cost free. If there is any breakdown with product after 90 days with video or picture proof provided, we will give customer free component to replace, with freight cost paid by customer.
These conditions below shall not be in warranty range.
NO FREE WARRANTY FOR THE FOLLOWING SITUATION:
24. The product is used for more than 3 years.
2. The product is not purchased through official or authorized channels.
3. The product breakdown because the user does not follow product instructions to use or maintain the product.
Warranty
The AUTOOL and its accessories are guaranteed for 3 years warranty from the date the products are delivered to customer.
Package included:
Autool Smoke Leak Detector1
Black Tube Drain Plug1
Smoke Tube1
Red Tube Drain Plug1
Hook1
Oil Measuring Bottle1
Power Cable1
Universal Tapered Inlet Adapter 1
Adapter 1
Universal Airbag Inlet Adapter1
Valve Core Interface1
Manual1
EVAP Adapter1
Product Qualification Certificate1